Recalibration of mobile products
Recalibration guarantees the accuracy and quality of your test and measurement values
Ensuring the Accuracy and Reliability of NDT Instruments, Probes, and Standards. FOERSTER emphasizes the vital role of calibration in upholding the precision and reliability of non-destructive testing (NDT) results. Calibration involves comparing measured values with traceable standards to ensure accuracy and consistency in parameters like electrical conductivity, hardness, coercive force and magnetic flux density.
Regular recalibration is crucial for demonstrating the quality of test and measurement outcomes, aligning them with industry standards and regulations.
FOERSTER's calibration services offer sample certificates illustrating the covered norms and the option for additional specifications upon request.
The comprehensive factory calibration service ensures the continuous high quality and optimal performance of FOERSTER systems, devices, instruments, and standards.
Product highlights
Calibration Certificates
|
DEFECTOMETER |
|
| DEFECTOMETER 2.837, Order-Nr: 1459147 | Calibration Certificate - DEFECTOMETER M |
| DEFECTOMETER M 1.837, Order-Nr: 1880756 | Calibration Certificate - DEFECTOMETER M |
|
DAkkS akkredited depth measurement of calibration block (3x notch) (1.837.01-11xx), Order-Nr: 2345501 |
Calibration Certificate - Crack Depth and Crack Width |
|
Depth measurement of calibration block (3x notch) (2.142/ 2.154/ 2.164/ 2.835/ 2.836/ 2.837/ 1.837); Order-Nr: 2325241 |
Calibration Certificate - Crack Depth and Crack Width |
|
Calibration of 1 DEFECTOMETER probe, Order-Nr: 2826313 |
Calibration Certificate - DEFECTOMETER M probe |
|
Calibration of 1 DEFECTOMETER probe, Order-Nr: 2244691 |
Calibration Certificate - DEFECTOMETER M probe |
|
|
|
|
MAGNETOSCOP |
|
|
MAGNETOSCOP 1.070 incl. probe, Order-Nr: 2084970 |
Calibration Certificate - MAGNETOSCOP 1.070 |
|
MAGNETOSCOP 1.070, Order-Nr: 1880756 |
Calibration Certificate - MAGNETOSCOP 1.070 |
|
MAGNETOSCOP 1.070 probe, Order-Nr: 2345501 |
Calibration Certificate - MAGNETOSCOP 1.070 |
|
Reference standard permeability 1.070 (30kA/m), Order-Nr: 2085003 |
Calibration Certificate - Permeability Standards |
|
Reference standard permeability 1.068 / 1.069 (10kA/m), Order-Nr: 1269291 |
Calibration Certificate - Permeability Standards |
|
|
|
|
SIGMATEST |
|
|
SIGMATEST 2.070 calibration instrument with probe and double standard, Order-Nr: 2257688 |
Calibration Certificate - SIGMATEST 2.070 + probe 14 mm (Ti) Calibration Certificate - Conductivity standard, 4 MS/m (PTB certified) Calibration Certificate - Conductivity standard, 58 MS/m (PTB certified) |
|
SIGMATEST 2.070 calibration of 1 probe, Order-Nr: 2257700 |
Calibration Certificate - SIGMATEST 2.070 + probe 14 mm (Ti) |
|
SIGMATEST 2.069 calibration instrument with probe and double standard, Order-Nr: 1881647 |
Calibration Certificate - SIGMATEST 2.069 + probe 8mm Calibration Certificate - Conductivity standard, 4 MS/m (PTB certified) Calibration Certificate - Conductivity standard, 58 MS/m (PTB certified) |
|
SIGMATEST 2.069 calibration of 1 probe, Order-Nr: 2219824 |
|
|
SIGMATST 2.069/2.070 calibration of a 8mm flex probe, Order-Nr: 2219832 |
|
|
Readjustment of 1 probe (if the calibration of a probe failed 2.069/2.070), Order-Nr: 2306735 |
|
|
Readjustment of 1 probe (if the calibration of a probe failed 2.069/2.070), Order-Nr: 2321629 |
|
|
Addon calibration (2.070/2.069 instrument): Measurement of the excitation frequencies, Order-Nr: 2306743 |
|
|
Addon calibration (2.070/2.069 probe or standard): Measurement with different limits (example: 1%IACS deviation), Order-Nr: 2306751 |
|
|
Addon calibration (2.070/2.069 probe or standard): List of the 10 individual measurement values for each frequency, Order-Nr: 2306760 |
|
|
Conductivity measurement with certificate of a customer part (NPL), Order-Nr: 2278120 |
Calibration Certificate - Conductivity standard, 16 MS/m (PTB certified) |
|
Addon calibration (2.070/2.069 probe or standard): Appendix for verified standards DGQT 4.2.0368 or AITM6-6008, Order-Nr: 2306778 |
Calibration Certificate - Confirmation AITM6-6004 + AITM6-6008 |
|
Calibration standard based on NPL (SIGMATEST 2.070) (5 frequencies), Order-Nr: 2278111 |
Calibration Certificate - Conductivity standard, 58 MS/m (NPL certified) |
|
Calibration standard based on PTB (SIGMATEST 2.069) (5 frequencies), Order-Nr: 2826348 |
Calibration Certificate - Conductivity standard, 58 MS/m (PTB certified) |
|
Conductivity measurement with certificate of a customer part (PTB), Order-Nr: 2306727 |
Calibration Certificate - Conductivity standard, 16 MS/m AI (PTB certified) |
|
|
|
|
SONODUR |
|
|
Factory calibration of hand test probe with certificate, Order-Nr: 2229641 Note: includes the incoming inspection of the probe (does not include the incoming inspection & function test of the instrument) |
|
|
Calibration according to DIN 50159-2; DAkkS certificate for SONODUR instrument and 1 probe, Order-Nr: 2231115 Note: Requires factory calibration of the probe (2229641) and incoming inspection & function test of instrument (4990200) beforehand |
Calibration Certificate - Portable Hardness Tester According to UCI |
|
|
|
|
TCM |
|
|
TCM 2.142 calibration of instrument, Order-Nr: 2319993 |