STATOGRAPH probes
Probes for the non-destructive crack detection of complex workpieces using eddy current
Eddy current testing for safe components. We aim to produce safe component for the automotive sector. This is why we use fixed and rotating differential eddy-current probes with high test sensitivity for component crack testing. A comprehensive selection of different standard sensors is available to suit various test tasks.
FOERSTER designs and manufactures individual special sensors tailored to meet your requirements for any test task requiring special solutions.
Information regarding the calibration procedure, decision rules and assessment of conformity can be found in the example calibration certificate.
Product highlights
Technical information
| PROBES | |
| Clearance compensation: | optional |
| Width of coverage: | 0,8 mm to 5 mm |
| Frequency range: | up to 1 MHz and 10 MHz |
| Test sensitivity: | High |
| Electrical and mechanical stability: | High |
| ROTATING HEAD | |
| Rotating probe speed: | nmax=15,000 min-1 |
| Frequency range: | 100 kHz - 1 MHz |